<< Click to Display Table of Contents >> Navigation: General instructions > Parametric analysis input data |
Parametric analysis input data
Data regarding the parametric analysis are:
•Project title: Enter a small description about the project. This text will appear on top of the results report.
•L/B: This value defines the footing length to footing width ratio.
•B min: Enter a value for the minimum footing width that will be used in the parametric analysis.
•B max: Enter a value for the maximum footing width that will be used in the parametric analysis.
•q min: Enter a value for the minimum net footing pressure that will be used in the parametric analysis.
•q max: Enter a value for the maximum net footing pressure that will be used in the parametric analysis.
Copyright © 2006, GeoLogismiki