<< Click to Display Table of Contents >> Navigation: Overview > Defining CPT and liquefaction calculation parameters > B&I 2014 |
B&I 2014 calculation properties
•User defined fines content: If checked the software will use custom FC data input instead of using the formula from B&I 2014. If the Default BI is checked then for CPT points that no custom data is available the software will use the value form the B&I 2014 formula instead of the default value input
•CRR PL: The liquefaction probability value that will be used to calculate CRR, Β&Ι 2014 default value is 16%
•C(FC): This is the fitting parameter used in the relationship for FC estimation, default value proposed is 0.00